TANDBERG DATA

TDC 6122

Device Type

Tape Drive

Interface

SCSI-2

Format

QIC-5010-DC; QIC-5010-DC single-ch.; QIC-5GB; QIC-2GB; QIC-1000C; QIC-525; QIC-150; QIC-120

Sustained Transfer Rate

Unidentified

Size

5.25 in. half height

View

Top

CONNECTIONS

Function

Label

Ground connector

CN1

USER CONFIGURABLE SETTINGS

Setting

Label

Position

»

Factory configured - do not alter.

JP1/Pins 5 & 6

Unidentified

»

Factory configured - do not alter.

JP1/Pins 7 & 8

Unidentified

»

Factory configured - do not alter.

JP1/Pins 9 & 10

Unidentified

»

Factory configured - do not alter.

JP1/Pins 11 & 12

Unidentified

»

Factory configured - do not alter.

JP1/Pins 13 & 14

Unidentified

»

Factory configured - do not alter.

JP1/Pins 15 & 16

Unidentified

»

Factory configured - do not alter.

JP1/Pins 17 & 18

Unidentified

»

Factory configured - do not alter. (Parity enable/disable)

JP1/Pins 19 & 20

Unidentified

 

Termination enabled

JP1/Pins 29 & 30

Closed

 

Termination disabled

JP1/Pins 29 & 30

Open

Note: Pins 2 and 4 are used to connect the drive to certain test tools related to serial in/out communication.

DRIVE SELECT ID

Drive ID

JP1/Pins 21 & 22

JP1/Pins 23 & 24

JP1/Pins 25 & 26

JP1/Pins 27 & 28

0

Open

Open

Open

Open

1

Closed

Open

Open

Open

2

Open

Closed

Open

Open

3

Closed

Closed

Open

Open

4

Open

Open

Closed

Open

5

Closed

Open

Closed

Open

6

Open

Closed

Closed

Open

7

Closed

Closed

Closed

Open

8

Open

Open

Open

Closed

9

Closed

Open

Open

Closed

10

Open

Closed

Open

Closed

11

Closed

Closed

Open

Closed

12

Open

Open

Closed

Closed

13

Closed

Open

Closed

Closed

14

Open

Closed

Closed

Closed

15

Closed

Closed

Closed

Closed

TEST FUNCTIONS

Function

Pins 21 & 22

Pins 23 & 24

Pins 25 & 26

Pins 27 & 28

Read/Write Selftest

Open

Open

X

X

Extended Drive Selftest

Closed

Open

X

X

Mainboard Selftest

Open

Closed

X

X

Combined Selftest

Closed

Closed

X

X

Continuous Mode

X

X

X

Closed

Stop-at-Failure Mode

X

X

Closed

X

Note: Pins 1 & 3 jumpered for all testing purposes. ‘X’ means don’t care.

TERMINATION POWER SELECTION

Setting

JP1/Pins 31 & 32

TERMPWR supplied by drive

Closed

TERMPWR supplied by SCSI interface to drive

Open

MANUFACTURERS RECOMMENED MEDIA

Tape

Capacity Without Compression

Capacity With Compression

QIC-5010-DC

13.0 GB

Unidentified

QIC-5010-DC single-ch.

13.0 GB

Unidentified

QIC-5GB

5.0 GB

Unidentified

QIC-2GB

2.0 GB

Unidentified

QIC-1000C

1.0 GB

Unidentified

QIC-525

525 MB

Unidentified

QIC-150

155 MB

Unidentified

QIC-120

120 MB

Unidentified

Hosted by uCoz