THOMAS-CONRAD CORPORATION

TC3042-ST (Fiber Optic) TCNS 8-BIT

NIC Type

TCNS (proprietary)

Transfer Rate

100Mbps

Data Bus

8-bit ISA

Topology

Star

Wiring Type

Fiber optic cable

Boot ROM

Available

NODE ADDRESS

Node

SW2/1

SW2/2

SW2/3

SW2/4

SW2/5

SW2/6

SW2/7

SW2/8

 

0

-

-

-

-

-

-

-

-

»

1

On

On

On

On

On

On

On

Off

 

2

On

On

On

On

On

On

Off

On

 

3

On

On

On

On

On

On

Off

Off

 

4

On

On

On

On

On

Off

On

On

 

251

Off

Off

Off

Off

Off

On

Off

Off

 

252

Off

Off

Off

Off

Off

Off

On

On

 

253

Off

Off

Off

Off

Off

Off

On

Off

 

254

Off

Off

Off

Off

Off

Off

Off

On

 

255

Off

Off

Off

Off

Off

Off

Off

Off

 

Notes: Node address 0 is used for messaging between nodes and must not be used. A total of 255 node address settings are available. The switches are a binary representation of the decimal node addresses. Switch 8 is the Least Significant Bit and switch 1 is the Most Significant Bit. The switches have the following decimal values: switch 8=1, 7=2, 6=4, 5=8, 4=16, 3=32, 2=64, 1=128. Turn off the switches and add the values of the off switches to obtain the correct node address. (On=0, off=1)

CONNECTIONS

Purpose

Location

Receive (dark colored)

CN1

Transmit (light colored)

CN2

WAIT STATE

Setting

JP2

»

Zero wait states enabled

Closed

 

Zero wait states disabled

Open

INTERRUPT REQUEST

IRQ

JP3

JP4

JP5

JP6

JP7

JP8

»

2

Closed

Open

Open

Open

Open

Open

 

3

Open

Closed

Open

Open

Open

Open

 

4

Open

Open

Closed

Open

Open

Open

 

5

Open

Open

Open

Closed

Open

Open

 

6

Open

Open

Open

Open

Closed

Open

 

7

Open

Open

Open

Open

Open

Closed

BASE MEMORY ADDRESS

Memory Address

SW1/1

SW1/2

SW1/3

SW1/4

SW1/5

SW1/6

 

C000h

Off

Off

On

On

On

On

 

C400h

Off

Off

On

On

On

Off

 

C800h

Off

Off

On

On

Off

On

 

CC00h

Off

Off

On

On

Off

Off

»

D000h

Off

Off

On

Off

On

On

 

D400h

Off

Off

On

Off

On

Off

 

D800h

Off

Off

On

Off

Off

On

 

DC00h

Off

Off

On

Off

Off

Off

 

Note : Switches 7 & 8 are always in the on position.

I/O BASE ADDRESS

Address

SW3/1

SW3/2

SW3/3

SW3/4

SW3/5

SW3/6

»

2E0h

Off

On

Off

Off

Off

On

 

2F0h

Off

On

Off

Off

Off

Off

 

300h

Off

Off

On

On

On

On

 

310h

Off

Off

On

On

On

Off

 

320h

Off

Off

On

On

Off

On

 

330h

Off

Off

On

On

Off

Off

 

340h

Off

Off

On

Off

On

On

 

350h

Off

Off

On

Off

On

Off

 

360h

Off

Off

On

Off

Off

On

 

370h

Off

Off

On

Off

Off

Off

 

380h

Off

Off

Off

On

On

On

 

390h

Off

Off

Off

On

On

Off

 

3A0h

Off

Off

Off

On

Off

On

 

3B0h

Off

Off

Off

On

Off

Off

 

3C0h

Off

Off

Off

Off

On

On

 

3D0h

Off

Off

Off

Off

On

Off

 

3E0h

Off

Off

Off

Off

Off

On

 

3F0h

Off

Off

Off

Off

Off

Off

OPERATING MODE

Mode

SW3/7

»

Enhanced mode

On

 

Compatible mode

Off

Note: Enhanced mode optimizes performance and minimizes conflicts of your hardware by using a Thomas-Conrad

Hosted by uCoz