COMPU-SHACK PRODUCTION, GMBH

CS-FDDI PCI-MMF-SAS

Card Type

Network Interface Card

NIC Type

FDDI

Maximum Onboard Memory

Unidentified

Boot ROM

Available

Network Transfer Rate

100Mbps

Topology

Ring

Wiring Type

Fiber optic cable

Data Bus

32-bit PCI

CONNECTIONS

Function

Label

Fiber-optic connector via MIC

CN1

USER CONFIGURABLE SETTINGS

Function

Label

Position

»

Boot ROM disabled

JP13/A

Open

 

Boot ROM enabled

JP13/A

Closed

»

Factory configured - do not alter

JP13/E

Unidentified

»

Factory configured - do not alter

JP3

Unidentified

BASE I/O ADDRESS SELECTION

Address

JP13/B

JP13/C

JP13/D

 

200h-21Fh

Closed

Closed

Closed

 

220h-23Fh

Closed

Closed

Open

 

240h-25Fh

Closed

Open

Closed

 

280h-29Fh

Closed

Open

Open

»

300h-31Fh

Open

Closed

Closed

 

320h-33Fh

Open

Closed

Open

 

340h-35Fh

Open

Open

Closed

DIAGNOSTIC LED(S)

LED

Color

Status

Condition

LED1

Unidentified

On

See conditions in note below

LED1

Unidentified

Off

See conditions in note below

LED2

Red

On

Cable fault detected (SDDI only)

LED2

Red

Off

No cable fault detected (SDDI only)

LED3

Green

On

Network connection is good

LED3

Green

Off

Network connection is broken

LED4

Yellow

On

Data is being transmitted/received

LED4

Yellow

Off

Data is not being transmitted/received

Note: LED1 varies depending on model. Green (On: UTP link is good, Off: UTP link is broken); Red (On: Illegal connection, Off: Valid connection); or Orange (On: Line error alarm activated, Off: Line error alarm not activated).

USER CONFIGURABLE SETTINGS

Note: JP14 and JP16 are unidentified.

Hosted by uCoz