ANCOR COMMUNICATIONS, INC.

FCS 266 SBUS, FCS 1062 SBUS

NIC Type

Fiber Channel

Processor

Intel i960

Processor Speed

33MHz

Chipset

Ancor Communications VHSCI 4

Maximum Onboard Memory

1MB VRAM/512KB SRAM/256KB Flash ROM/128KB ROM

Network Transfer Rate

265.6125Mbps (FCS 266 SBUS)

1062.5Mbps (FCS 1062 SBUS)

Data Bus

SBus

Topology

Star/Peer-Peer

Wire Type

Fiber optic cable

Boot ROM

Not available

CONNECTIONS

Function

Label

Function

Label

Receive fiber optic SC connector

CN1

Transmit fiber optic SC connector

CN2

DIAGNOSTIC LED(S)

LED

Color

Status

Condition

LED1

Unidentified

On

Card is receiving data

LED1

Unidentified

Off

Card is not receiving data

LED2

Unidentified

On

Card is transmitting data

LED2

Unidentified

Off

Card is not transmitting data

LED3

Green

Blinking

Normal operation

LED3

Green

1 blinks

EPROM failed checksum test

LED3

Green

2 blinks

Processor memory failed self-test

LED3

Green

3 blinks

Buffer memory failed self-test

LED3

Green

4 blinks

FPGA failed self-test

LED3

Green

5 blinks

Flash ROM failed checksum test

LED3

Green

6 blinks

Flash ROM ID failed self-test

LED3

Green

7 blinks

OLC loopback test failed

LED3

Green

8 blinks

Chipset register failed self-test

LED3

Green

9 blinks

Timer failed self-test

LED3

Green

Off

Power is off or processor is not functioning