INFORTREND TECHNOLOGY, INC.

IFT-2000A

Data bus:

32-bit PCI

Size:

Three-quarter length, full-height card

Hard drive supported:

Up to seven Fast SCSI-2 devices

Floppy drives supported:

None

CONNECTIONS

Function

Location

4-pin connector - drive active LED

JP2

50-pin SCSI connector - internal channel 0

JP4

50-pin SCSI connector - external channel 0

JP17

9-pin serial port - external

JP20

USER CONFIGURABLE SETTINGS

Function

Location

Setting

»

Factory configured - do not alter

JP1

pins 1 & 2 closed

»

Factory configured - do not alter

JP10

open

»

Factory configured - do not alter

JP11

open

»

Factory configured - do not alter

JP15

open

ONBOARD CPU SELECTION

CPU

JP9

JP18

486SX-25

pins 1 & 2 closed

pins 2 & 3 closed

486DX-25

pins 1 & 2 closed

pins 1 & 2, 3 & 4 closed

486SX-33

pins 2 & 3 closed

pins 2 & 3 closed

486DX-33

pins 2 & 3 closed

pins 1 & 2, 3 & 4 closed

DRAM CONFIGURATIONS

Size

Bank 0

2 MBytes

(1) 512K x 36

4 MBytes

(1) 1M x 36

8 MBytes

(1) 2M x 36

16 MBytes

(1) 4M x 36

32 MBytes

(1) 8M x 36

Note: Minimum of 2 MBytes DRAM must be installed with/without parity function.

Minimum of 4 MBytes DRAM suggested for RAID-3 and RAID-5 configurations.

MISCELLANEOUS NOTES

Pin 1 for jumpers JP1, JP9, JP18 are designated for diagram purposes only.