R O 3 1 9 9 A    RODIME
NO MORE PRODUCED                                      Native|  Translation
                                                      ------+-----+-----+-----
Form                 3.5"/HH               Cylinders    1216|     |     |
Capacity form/unform   163/      MB        Heads           7|     |     |
Seek time   / track  18.0/ 5.0 ms          Sector/track     |     |     |
Controller           IDE / AT              Precompensation
Cache/Buffer            64 KB DUAL-PORTED  Landing Zone
Data transfer rate    1.250 MB/S int       Bytes/Sector      512
                      4.000 MB/S ext
Recording method     RLL 2/7                        operating  | non-operating
                                                  -------------+--------------
Supply voltage     5/12 V       Temperature *C        10 50    |    -40 70
Power: sleep              W     Humidity     %        10 85    |      5 90
       standby            W     Altitude    km    -0.305  3.048|
       idle           7.4 W     Shock        g        10       |     50
       seek               W     Rotation   RPM      3600
       read/write         W     Acoustic   dBA        50
       spin-up            W     ECC        Bit
                                MTBF         h      30000
                                Warranty Month
Lift/Lock/Park     YES          Certificates


**********************************************************************
                        L   A   Y   O   U   T
**********************************************************************
RODIME   RO3059/3089/3129/3139/3199/3259-A  PRODU. SPECIFICATION 00221

  +---------------------------------------------------------++-+
  |                                                         || |Jumper
  |                                                         || |
  |                                                         |+-2
  |                                                         |XX I
  |                                                         |XX N
  |                                                         |XX T
  |    -LED-**                                              |XX E  P5
  |    +LED-**                                              |XX R
  |          *                                              |XX F
  |                                                         |XX A
  |                                                         |XX C
  |                                                         |XX E
  |                                                         |XX
  |                                                         |XX
  |                                                         |
  |                                                         |XX Power
  |                                                         |XX P4
  +---------------------------------------------------------+



**********************************************************************
                      J   U   M   P   E   R   S
**********************************************************************
RODIME   RO3059/3089/3129/3139/3199/3259-A  PRODU. SPECIFICATION 00221

 Jumper Setting
 ==============

 x = Jumper set at factory


 Jumpers
 -------
      +---------+  There are a total of 4 jumpers mounted adjacent to
      | o o o o |  the 40 way interface connector. They have the
      | o o o o |  following functions and are described in the order
      +---------+  as viewed from the end of the drive, with the first
        L L L L    jumper described nearest the 40 way interface
        K K K K    connector:
        2 1 4 5


 LK2  LED
 --------
      When fitted this jumper connects the LED to pin 39 of the inter-
      face.

 LK1  Dual Drives
 ----------------
      This jumper must be fitted to the Master when two drives are
      attached to a single bus. It allows the Master to sense that a
      slave has been attached.

 LK4  Master
 -----------
      When fitted this signifies that the drive jumpered is a Master.
      If two drives are connected on a single bus then only one drive
      may be jumpered in this way.

 LK5  IOChRdy.
 ------------
      When fitted this connects the IOChRdy signal from the drive to
      the interface. It is fitted when the drive is used in host
      systems that have a higher data transfer rate than the drive
      i.e. greater than 4 MBytes per second using a 1:1 interleave.


 There are four possible configurations in which a drive may be
 jumpered:

 1. Master, single drive with LED on interface   LK2 & LK4 fitted
 2. Master, single drive no LED on interface     LK4 only fitted
 3. Master, dual drive no LED on interface       LK4 & LK1 fitted
    or Slave, dual drive no LED on interface     no jumpers fitted
 4. Master, dual drive with LED on interface     LK4, LK1 & LK2 fitted
    or Slave, dual drive with LED on interface   LK2 only fitted

 The Master drive will always delay power-up by two seconds
 approximately to ensure that power surges on the +12V supply are
 minimised in a dual drive environment.


 LED Connection
 --------------
 There are two connections to be made to the LED on LED+ and LED-, the
 the two pins closest to the flexible circuit connector. This is an
 open drain output with a sink capability of 40 mA. No external
 current limiting resistor is necessary in this application. When a
 LED is connected on the interface (pin 39), an external current
 limiting resistor is required to be placed in series between pin 39
 and the +5V supply. The value of the current limiting resistor is
 dependant on the LED used and is typically 130 Ohms.



 P4   DC Power and pin connector assignments
 -------------------------------------------
      +------------+   pin 1    +12 VDC
      | 1  2  3  4 |   pin 2    +12 Volts Return
      +------------+   pin 3    + 5 Volts Return
                       pin 4    + 5 VDC



**********************************************************************
                      I   N   S   T   A   L   L
**********************************************************************
RODIME   RO3059/3089/3129/3139/3199/3259-A  PRODU. SPECIFICATION 00221

 Notes On Installation
 =====================

 Mounting Orientation
 --------------------
 The drive may be mounted in a system in any orientation.

 When installing the drive into an enclosure, the breather holes on
 the drive top cover must not be obstructed.

 There must be at least 0.1 inch clearance between the drive housing
 and the host frame to ensure functional vibration isolation.

 The drive may be mounted in either vertical or horizontal orienta-
 tion. It is supplied complete with anti-vibration mounts and threaded
 mounting brackets.


 Physical Description
 --------------------
 The user interface, is a 40 pin header with pin 20 removed to allow
 for polarisation. Up to two drives may be connected per interface
 cable.


 Cable Requirements
 ------------------
 A 40-conductor flat cable shall be used. The maximum cable length
 shall be two feet.


 Connector Requirements
 ----------------------
 The user interface cable connector shall be a 40 conductor connector
 consisting of two rows of 20 female contacts with adjacent contacts
 0.1 inch apart. The 3M P/N 3417-6040 or equivalent is suggested. A
 polarising key should be fitted to pin 20 of the connector.

 The power connector is a 4 pin AMP Mate-N-Lock type mounted on the
 end on the PCB. The recommended mating connector is AMP P/N
 1-480424-0 socket housing, using AMP pin P/N 350078-4, or equivalent.


 Transfer Rate
 -------------
 Data Transfer Rate Disk <-> Buffer      : 1.25-1.5 MBytes/second

 Data Transfer Rate Buffer <-> Host      : 4.0 MBytes/second
 (with disk transfer taking place simultaneously i.e. concurrent)

 Data Transfer Rate Buffer <-> Host      : 6.0 MBytes/second
 (Buffer to host transfer only i.e. non-concurrent)



**********************************************************************
                      F   E   A   T   U   R   E  S
**********************************************************************
RODIME   RO3059/3089/3129/3139/3199/3259-A  PRODU. SPECIFICATION 00221


 General Features
 ----------------
 The RO3009A series of disk drives are random access storage devices
 which uses between two and five 95mm magnetic disks to provide 46,
 70, 105, 112, 163 & 210 Million bytes of formatted on-line storage.

 - an 64 KByte dual ported FIFO buffer with look-ahead and zero-
   latency read algorithm.
 - 2.7 RLL coding.
 - 46 to 210 MBytes formatted capacity (M = 1 Million)
 - High performance rotary voice coil actuator with dedicated and
   embedded servo system.
 - Emulates IBM Task File.
 - Translate Mode.
 - 1:1 Interleave factor.
 - Data transfer rates up to 4 MBytes per second concurrent and 6
   MBytes per second non-concurrent.
 - Automatic defect management.


 Rotational Parameters
 ---------------------
 Disk Rotational Speed : 3600   36 RPM
 Spin-up time          : 12 Seconds maximum
 Spin down time        : 30 Seconds maximum


 Access Time
 -----------
 Single Seek           :  5 milliSeconds (average)
 Average Seek          : 18 milliSeconds (typical)
 Average Seek          : 20 milliSeconds (maximum)
 1225 Cylinders        : 38 milliSeconds (typical)
 1225 Cylinders        : 42 milliSeconds (maximum)


 Drive Life
 ----------
 The minimum drive service life is 36,000 power on hours. The drive is
 capable of 10,000 start/stop operations during service life.


 MTBF
 ----
 The Mean time between failure (MTBF) of any of the Rodime RO3009A
 drives shall exceed 30,000 Hours.


 Service Goals
 -------------
 No preventative maintenance is required, and there are no adjustments
 on the drive. The repairs that may be effected on-site are replace-
 ment of the electronics board. The mean time to repair (MTTR) includ-
 ing initial verfication is 0.25 Hours.


 Data Reliability
 ----------------
 The read error rates quoted below assume that the data has been veri
 fied as written correctly and all media defects flagged. Furthermore
 the drive must be operating within the specified operational environ-
 ment.

 Recoverable data error rate  :   1 in 10(10) bits read
 Non recoverable error rate   :   1 in 10(12) bits read
 Unrecoverable error rate     :   1 in 10(14) bits read

 A recoverable error is defined as one which can be correctly read by
 re-reading the data.
 A non-recoverable error is defined as one where the ECC has to be
 applied in order to give the correct data.
 An unrecoverable error is defined as one which cannot be recovered by
 either re-reading the data or by application of the ECC.


 LED Error Codes
 ---------------
   Code    Definition
   -------+----------------------------------------------------
   06 hex |After stepping the maximum number of cylinders, the
          |drive could not achieve correct track zero status.
   07 hex |The spindle motor did not start at power up
   08 hex |Spindle motor failed initial +/-1% speed check at
          |power up.
   0A hex |No track crossing signal during seek.
   0B hex |No servo data
   0C hex |+12V supply failure

 All the above error codes are designated as FATAL, and resetting of
 the drive can only be done by powering the drive off then back on
 again.
 If the drive has an FATAL error, it will switch off power to both the
 voice coil and spindle motor and flash the external LED. The drive
 will still respond to commands sent across the interface, but will
 not execute any of them except READ & WRITE BUFFER, IDENTIFY and
 DIAGNOSTIC/SET PARAMETERS commands. A short duration flash of the LED
 signifies a '0' whilst a longer duration denotes a '1'.



Hosted by uCoz