I M P U L S E   1 0 5   S C S I / L P    PLUS DEVELOP.
NO MORE PRODUCED                                      Native|  Translation
                                                      ------+-----+-----+-----
Form                 3.5"/SLIMLINE         Cylinders    1219|     |     |
Capacity form/unform   100/      MB        Heads           4|     |     |
Seek time   / track  17.0/ 6.0 ms          Sector/track   42|     |     |
Controller           SCSI2 SINGLE-ENDED    Precompensation 65535
Cache/Buffer            64 KB              Landing Zone     1218
Data transfer rate    1.750 MB/S int       Bytes/Sector      512
                      4.000 MB/S ext SYNC
Recording method     RLL 2/7                        operating  | non-operating
                                                  -------------+--------------
Supply voltage     5/12 V       Temperature *C         4 50    |    -40 65
Power: sleep              W     Humidity     %         8 85    |      5 95
       standby            W     Altitude    km    -0.060  3.000| -0.060 12.000
       idle           6.5 W     Shock        g         6       |     60
       seek               W     Rotation   RPM
       read/write         W     Acoustic   dBA        45
       spin-up            W     ECC        Bit
                                MTBF         h      60000
                                Warranty Month        12
Lift/Lock/Park     YES          Certificates                                  

**********************************************************************
                        L   A   Y   O   U   T
**********************************************************************
QUANTUM  SCSI DRIVES JUMPER SETTING

  +---------------------------------------------------------+
  |                       +--A1-+                        ++ |XX
  |                       +-----+                        || |XXI
  |                                                      || |XXT
  |                                           Terminator || |XXE
  |                                                      ++ |XXR
  |                                                      ++ |XXF
  |  +-+                                                 || |XXA
  |  | A2                                                || |XXC
  |  +-+                                      Terminator || |XXE
  |                                                      ++ |XX
  |                                                         |XX
  |                                                         |
 ++ -                                                       |XX Power
 ++LED+                                                     |XX
  +---------------------------------------------------------+
 RE = For factory use only (RESERVED)

 Jumper A1
 ---------
   +--+--+--+--+--+
   |PK|TE|A0|A1|A2| Drives: Trailblazer 420/850
   +--+--+--+--+--+         Fireball 540/1080


 Jumper A1
 ---------
   +--+--+--+
   |A0|A1|A2| Drives: LPS 127/170/340
   +--+--+--+         Maverick 270/540


 Jumper A1
 ---------
   +--+--+--JP1
   |A0|A1|A2| Drives: ELS 42/85/127/170
   +--+--+--+


 Jumper A1
 ---------
   +--+--+--+ +--+--+--+
   |RE|RE|P0| |A0|A1|A2|  Drives: LPS 270/540
   +--+--+--+ +--+--+--+  Ligthning 365/540/730



 Jumper A1
 ---------
   +--+--+--+ +--+--+--+
   |SS|EP|WS| |A2|A1|A0|  Drives: 40/80/120/170/210
   +--+--+--+ +--+--+--+  LPS 52/80/105


 Jumper A1
 ---------
   +--+--+--+ +--+--+--+
   |SS|EP|WS| |A0|A1|A2|  Drives: LPS 120/240
   +--+--+--+ +--+--+--+


 Jumper A2
 ---------

 +--+
 |  |
 |A2| Drives: LPS 270/540
 |A1|         Ligthning 365/730
 |A0|         Fireball 540/1080
 |RE|
 +--+



**********************************************************************
                      J   U   M   P   E   R   S
**********************************************************************
QUANTUM  SCSI DRIVES JUMPER SETTING

 Jumper Setting
 ==============


 J2  SCSI ID
 -----------
   +----------+-----------------------+
   | SCSI ID  |        Jumpers        |
   |          |  A2   |  A1   |  A0   |
   +----------+-------+-------+-------+
   |    0     | OPEN  | OPEN  | OPEN  |
   |    1     | OPEN  | OPEN  | CLOSED|
   |    2     | OPEN  | CLOSED| OPEN  |
   |    3     | OPEN  | CLOSED| CLOSED|
   |    4     | CLOSED| OPEN  | OPEN  |
   |    5     | CLOSED| OPEN  | CLOSED|
   |    6     | CLOSED| CLOSED| OPEN  | Factory default
   |    7     | CLOSED| CLOSED| CLOSED|
   +----------+-------+-------+-------+
 A2 (MSB), A1, or A0 determine the drive's binary SCSI address ID.

 +--------------------+------+-------+--------------------------------
 |Quantum Drive Type  |Jumper|Setting|Description
 +--------------------+------+-------+--------------------------------
 |ProDrive 40/80/120/ |  SS  |OFF    |Self Seek Test disabled
 |170/210             |      |ON     |Self Seek Test enabled: For
 |LPS 52/80/105       |      |       |factory use ONLY! The test is
 |                    |      |       |indicated when power is applied
 |                    |      |       |to the drive. The test will
 |                    |      |       |continue until power is removed.
 |                    |      |       |On most drives, the LED remains
 |                    |      |       |on during the test (a flashing
 |                    |      |       |LED indicates a drive error).
 +--------------------+------+-------+--------------------------------
 |ProDrive 40/80/120/ |  EP  |OFF    |Parity Check disabled.
 |170/210             |      |ON     |Parity checking enabled: The
 |LPS 52/105/120/240  |      |       |drive generates parity
 |                    |      |       |information and performs parity
 |                    |      |       |checking of data across the SCSI
 |                    |      |       |bus.
 +--------------------+------+-------+--------------------------------
 |ProDrive 120/170/210|  WS  |OFF    |WaitSpin disabled. Drive motor
 |LPS52/80/105/120/240|      |       |power is applied when system
 |                    |      |       |power is applied to the
 |                    |      |       |computer.
 |                    |      |ON     |WaitSpin enabled. Drive motor
 |                    |      |       |power is applied when the host
 |                    |      |       |sends a START/STOP UNIT command.
 |                    |      |       |This option permits unit power
 |                    |      |       |sequencing so that the
 |                    |      |       |computer's power supply in a
 |                    |      |       |multidevice system is not over-
 |                    |      |       |loaded.
 +--------------------+------+-------+--------------------------------
 |ProDrive LPS 270/540|  PO  |OFF    |Parity checking disabled.
 |Ligthning365/540/730|      |ON     |Parity checking enabled: The
 |LPS 52/105/120/240  |      |       |drive generates parity
 |                    |      |       |information and performs parity
 |                    |      |       |checking of data across the SCSI
 |                    |      |       |bus.
 +--------------------+------+-------+--------------------------------
 |Trailblazer 420/850 |  TE  | OFF   |Termination disabled.
 |Fireball 540/1080   |      | ON    |Termination enabled. When the
 |                    |      |       |jumper is installed, it connects
 |                    |      |       |the termination resistors to the
 |                    |      |       |SCSI bus. Jumper TE should be
 |                    |      |       |ON when the drive is the last
 |                    |      |       |physical device on the SCSI bus.
 +--------------------+------+-------+--------------------------------
 |Fireball 540/1080   |  PK  |       |Terminals to PARKING jumper are
 |Trailblazer 420/850 |      |       |not used. The terminals are not
 |                    |      |       |connected.
 +--------------------+------+-------+--------------------------------



Hosted by uCoz