1 2 0 0    EZI
NO MORE PRODUCED                                      Native|  Translation
                                                      ------+-----+-----+-----
Form                 5.25"/FH              Cylinders    1216|     |     |
Capacity form/unform   171/      MB        Heads           8|     |     |
Seek time   / track  25.0/     ms          Sector/track   36|     |     |
Controller           ESDI                  Precompensation
Cache/Buffer            32 KB FIFO BUFFER  Landing Zone
Data transfer rate    1.250 MB/S int       Bytes/Sector      512
                            MB/S ext
Recording method     RLL                            operating  | non-operating
                                                  -------------+--------------
Supply voltage     5/12 V       Temperature *C        10 45    |      3 60
Power: sleep              W     Humidity     %        20 80    |
       standby            W     Altitude    km                 |
       idle               W     Shock        g                 |
       seek               W     Rotation   RPM      3524
       read/write         W     Acoustic   dBA
       spin-up            W     ECC        Bit
                                MTBF         h      30000
                                Warranty Month
Lift/Lock/Park     YES          Certificates                                  

**********************************************************************
                        L   A   Y   O   U   T
**********************************************************************
SIEMENS  MEGAFILE 1200/1300  HANDLING INSTRUCTIONS S26371-K64-V1-X7619

  +---------------------------------------------------------+  1
  |               +-J12                  +--J9--+ J11----1  |XX
  |               +-+                    +------+  +-----+  |XX J1
  |                                  Terminator    Address  |XX
  |                                                         |XX
  |                                                         |XX
  |                                                         |XX
  |                                                         |XX
  |                                                         |XX
  |                                                         |
  |                                                         |XX1
  |                                                         |XX J2
  |                                                         |XX
  |                                                         |XX
  |                                                         |XX
  |                                                         |
  |                                                         |XX J3
  |                                                         |XX Power
  +---------------------------------------------------------+







     +----------------------------------+
     |                                  |
     |                                  |
     |                                  |
     |      +J8 Grounding Connector     |
     |      ++                          |
     |   J3     J2   1      J1        1 |
     | XXXXXX XXXXXXxX XXXXXXXXXXXXXXxX |
     +----------------------------------+



**********************************************************************
                      J   U   M   P   E   R   S
**********************************************************************
SIEMENS  MEGAFILE 1200/1300  HANDLING INSTRUCTIONS S26371-K64-V1-X7619

 Jumper Setting
 ==============


 J11 Address Jumper
 ------------------
 +-------------+         +-------------+
 |X o o o o o o| Drive 1 |o X o o o o o| Drive 2
 |X o o o o o o|         |o X o o o o o|
 +-------------+         +-------------+
  1 2 3 4 5 6 7           1 2 3 4 5 6 7


 +-------------+         +-------------+
 |o o X o o o o| Drive 3 |o o o X o o o| Drive 4
 |o o X o o o o|         |o o o X o o o|
 +-------------+         +-------------+
  1 2 3 4 5 6 7           1 2 3 4 5 6 7

 +-------------+         +-------------+
 |o o o o X o o| Drive 5 |o o o o o X o| Drive 6
 |o o o o X o o|         |o o o o o X o|
 +-------------+         +-------------+
  1 2 3 4 5 6 7           1 2 3 4 5 6 7

 +-------------+
 |o o o o o o X| Drive 7
 |o o o o o o X|
 +-------------+
  1 2 3 4 5 6 7


 J12 Automatic Spin up jumper (Upper than REV 130)
 -------------------------------------------------
 ON  Automatic Spin up
 OFF Power on Command



**********************************************************************
                      I   N   S   T   A   L   L
**********************************************************************
SIEMENS  MEGAFILE 1200/1300  HANDLING INSTRUCTIONS S26371-K64-V1-X7619

 Notes on Installation
 =====================

 Installation direction
 ----------------------

     PCBA down                     PCBA left           PCBA right
   +-----------------+             +--+                       +--+
   |                 |             |  +-----+           +-----+  |
   |                 |             |  |     |           |     |  |
 +-+-----------------+-+           |  |     |           |     |  |
 +---------------------+           |  |     |           |     |  |
                                   |  |     |           |     |  |
     PCBA up                       |  |     |           |     |  |
 +---------------------+           |  +-----+           +-----+  |
 +-+-----------------+-+           +--+                       +--+
   |                 |
   |                 |
   +-----------------+



 Recommended Cables
 ------------------
 Interface Cable 50 Conductor flat ribbon twisted pair or equivalent

 Power Cable 18 AWG wire with a 4-pin AMP Mate-N-Lok Connector P/N AMP
 1-480424-0

 Frame Ground 18 AWG wire with AMP P/N 61761-2 or equivalent


 Optional Front Panel
 --------------------
 REV 1 to REV 129   No. S26371-H30-V1 (C26371-H30-C4) suitable to
 (metal shielded)   metal plate frame
                    2 LED, Red   = error
                           Green = error

 REV 130            No. S26371-H30-V2 (C26371-H30-C4) suitable to
 (plastic panel)    metal plate frame
                    1 LED, Red = drive selected

 Upper than REV 131 No. S26371-H30-V3 (C26371-H23-C321) suitable to
 (plastic panel)    die cast frame
                    1 LED, Red = drive selected


 Cable Interconnection
 ---------------------

   +-----------+                                +-----------------+
   |           +---o---Control------------------+J1     Drive 1   |
   |           |   |    +-------Data------------+J2               |
   |           |   |    |             +-Power---+J3  J8    ...    |
   |           |   |    |             |         +-----+-----------+
   |           |   |    |             |    +-Frame----+
   |           |   |    |             |    |    +-----------------+
   |Controller |   o----+-------------+----+----+J1     Drive 2   |
   |           |   |    | +-----------+----+----+J2               |
   |           |   |    | |           o----+----+J3  J8    ...    |
   |           |   |    | |           |    |    +----+------------+
   |           |   |    | |           |    o---------+
   |           |   |    | |           |    |    +-----------------+
   |           |   o----+-+-----------+----+----+J1     Drive 3   |
   |           |   |    | | +---------+----+----+J2               |
   |           +---+Data+ | |         o----+----+J3  J8    ...    |
   |           +---+-Data-+ |         |    |    +-----+-----------+
   |           |   |        |         |    o----------+
   |           +---+-Data---+         |    |    +-----------------+
   |           |   +------------------+----+----+J1     Drive 7   |
   |           +-----Data-------------+----+----+J2               |
   |           |                      o----+----+J3  J8    XXX    |
   +-----------+                      |    |    +-----+-----------+
                       DC voltages----+    o----------+
                                           |
                       Frame Ground--------+


 ... = Terminator Pack removed

 XXX = Terminator Pack installed

 Terminator installed only in the last physical drive in a chain.
 Max. cable length 3 meters.


 Screws
 ------
 Mounting Holes 2 per side #6-32 UNC-2B 0.14 (3.5) deep (4x)
 Mounting Holes 4 on bottom #6-32 UNC-2B, 0.4 (10) deep (4x)

 NOTE
 Mounting Holes 2 per side are different in depth to the mounting
 holes 4 on bottom.


 J3   DC Power and pin connector assignments
 -------------------------------------------
 pin 1    +12 VDC
 pin 2    +12 Volts Return
 pin 3    + 5 Volts Return
 pin 4    + 5 VDC



Hosted by uCoz