S D - 3 4 0 H - 0 0 TEAC
NO MORE PRODUCED Native| Translation
------+-----+-----+-----
Form 3.5"/SLIMLINE Cylinders 1050| | |
Capacity form/unform 43/ MB Heads 2| | |
Seek time / track 19.0/ 8.0 ms Sector/track 40| | |
Controller SCSI1 SINGLE-ENDED Precompensation
Cache/Buffer 28 KB Landing Zone
Data transfer rate 1.500 MB/S int Bytes/Sector 512
MB/S ext
Recording method RLL 2/7 operating | non-operating
-------------+--------------
Supply voltage 5/12 V Temperature *C 5 50 | -40 60
Power: sleep W Humidity % 8 80 | 8 80
standby 0.5 W Altitude km -0.300 3.000| -0.300 12.000
idle 4.4 W Shock g 5 | 70
seek 6.7 W Rotation RPM 3600
read/write 4.8 W Acoustic dBA 50
spin-up W ECC Bit
MTBF h 30000
Warranty Month
Lift/Lock/Park - Certificates CSA,TUV,UL478,VDE
**********************************************************************
L A Y O U T
**********************************************************************
TEAC SD-340H-00 SPECIFICATION P/N 10530579-02 REV. A
+---------------------------------------------------------++-+Strap
| || |SP
| |+-+S0 3
| |XX1
| |XX Inter-
| |XX face
| |XX
| |XX
| |XX
|++LED |XX
|++ |XX
| |XX
| |XX
| |XX
| |
| |XX Power
| |XX
+---------------------------------------------------------+ 4
**********************************************************************
J U M P E R S
**********************************************************************
TEAC SD-340H-00 SPECIFICATION P/N 10530579-02, REV. A
Jumper Setting
==============
Strap
+-------+ +------------------------1+ +-----+
|4 3 2 1| |:::::::::::::::::::::::::| |ooooo|
PCB---+-------+-+------------------------2+-+-----+
Power Interface |||||
S3+|||+SP
S2-+|+-S0
S1
Indicator
---------
The indicator on the front bezel shall be kept lit after the HDD
responds to a selection from an initiator, and before it completes
the execution of the command.
Parity Strap
------------
The S3 on the PCBA is used asa parity strap. When the S3 is shorted
with a plug, the input data (DB0 to DB7, DBP) shall be parity checked
(odd) by the HDD. When the S3 is open, no parity check shall be
executed. Factory setting: S3 shorted.
How to Set the SCSI ID
----------------------
The SCSI ID shall be set with the individual straps of SP, S0, S1,
and S2 on the PCBA.
The SP strap is to reserve the setting logic for S0, S1 and S2.
+----------+---------------+----------------+
| | SP=ON | SP=OFF |
+----------+---------------+----------------+
|SCSI ID | S2 S1 S0 | S2 S1 S0 |
+----------+---------------+----------------+
| 0 | ON ON ON | OFF OFF OFF |Factory Setting
+----------+---------------+----------------+
| 1 | ON ON OFF | OFF OFF ON |
+----------+---------------+----------------+
| 2 | ON OFF ON | OFF ON OFF |
+----------+---------------+----------------+
| 3 | ON OFF OFF | OFF ON ON |
+----------+---------------+----------------+
| 4 | OFF ON ON | ON OFF OFF |
+----------+---------------+----------------+
| 5 | OFF ON OFF | ON OFF ON |
+----------+---------------+----------------+
| 6 | OFF OFF ON | ON ON OFF |
+----------+---------------+----------------+
| 7 | OFF OFF OFF | ON ON ON |
+----------+---------------+----------------+
Note: The strap states are as follows:
1: Strap open
2: Strap short
Terminator factory setting: equipped
**********************************************************************
I N S T A L L
**********************************************************************
TEAC SD-340H-00 SPECIFICATION P/N 10530579-02 REV. A
Notes on Installation
=====================
Installation direction
----------------------
horizontally vertically
+-----------------+ +--+ +--+
| | | +-----+ +-----+ |
| | | | | | | |
+-+-----------------+-+ | | | | | |
+---------------------+ | | | | | |
| | | | | |
| | | | | |
+---------------------+ | +-----+ +-----+ |
+-+-----------------+-+ +--+ +--+
| |
| |
+-----------------+
Any of the four directions can be used.
The mounting cabinet for the HDD should be constructed so that no
distortion may be produced in the chassis.
A space of at least 1.5mm should also be allowed each of the HDA and
PCBA.
An insulation sheet should be stuck to the PCBA mounting face of the
HDD mounting cabinet, as required.
In each mounted position, the front can be raised by up to 30*.
Mounting positions other than those shown must be discussed
separately.
Screws
------
Tapped holes for installation each side: 3-M3 4 deep
Tapped holes for installation bottom: 4-#6-32 4 deep
Screws: M3 x 10
Front Bezel
-----------
Not equipped
LED Indicator color
-------------------
Green
Power Interface Connectors
--------------------------
HDD Side Connector AMP P/N 171826-4 (natural color)
or equivalent
Number of pins 4
Prevention method for mis-connection Mechanical protection of the
shape of the connector housing
Cable side matched connector AMP P/N 171822-4 (natural color)
or equivalent
Matched pin AMP P/N 170204-2 (AWG 20 to 26,
loose piece) or P/N 170262-2
(AWG 20 to 26, chained form),
or equivalent
Power cable The maximum power consumption of
the HDD and the voltage at the
power connector shall be taken
into consideration.
Power interface connector pin number
------------------------------------
pin 4 +12 VDC
pin 3 0 Volt
pin 2 0 Volt
pin 1 + 5 VDC
Electrical Characteristics
--------------------------
All the following specification apply to the interface connector of
the HDD. The input signal metioned below means the signal provided to
the HDD, and the output signal means the signal output from the HDD.
1. Input signal
a. Receiver: CMOS receiver with hysteresis
b. Input signal level
i. Low level (true): 0 0.8 VDC
ii. High level (false): 2.0 5.25 VDC
c. Maximum load current: 10 A (excluding the terminator)
d. Minimum hysteresis width: 0.2 VDC
2. Output signal
a. Driver: Open-drain type CMOS driver
b. Output signal level with the terminator connected
i. Low level (true): 0 0.5 VDC
ii. High level (false): 2.4 5.25 VDC
c. Driver sink current: 48mA (low-level voltage: 0.5 VDC)
3. TERMPWR signal
a. Output voltage: 4.0 5.25 VDC
b. Maximum output current: 1.0A
c. Output current limitation: Fuse (1.0A)
4. Terminator (effective for the 18 signals except for the TERMPWR
signal)
a. Terminator block: 11-pin SIP type x 2 pcs, detachable
b. Resistance values
i. +5V side: 220 5%
ii. 0V side: 330 5%
Signal Interface Connector and Cable
------------------------------------
1. Signal interface connector:
a. HDD side connector: Du Pont Electronics 68020-550
b. Number of pins and pitch: 2.54 (0.1 in) pitch, 50-pin pin
block header (25 pins in each of 2
rows with oddnumbered pins on the
top face of HDD)
c. Cable side matched connector: Du Pont Electronics 66902-050
2. Signal interface cable
a. Type: 50-core flat cable or 25-pair
twisted cable
b. Conductor size: AWG 28 or more
Equivalent parts may be used.
3. Characteristic impedance: 100 10% (recommended)
(When daisy chain is to be performed, match the characteristic
impedances of individual cables which each other.)
4. Maximum cable length: 6 meters
System Configuration
--------------------
Up to eight SCSI devices can be connected to the SCSI bus, including
initiators and targets. The SCSI devices mean devices provided with
interfaces which comply with the SCSI standard. The HDD is always
operated as a target, and it can be used in any configuration
(a, b, c).
The SCSI devices are allocated with SCSI IDs, which correspond to
the individual bits of the data bus.
With the HDD, SCSI IDs are set by strap connections on the PCB. The
priority is determined among the SCSI IDs; SCSI ID = 7 is the highest
priority, and SCSI ID = 0 is the lowest priority.
a. Single Initiator, Single Target
Initiator Target
+-------+ +-------+
| HOST +----SCSI-Bus--------+ HDD |
| +--------------------+ |
+-------+ +-------+
b. Single Initiator, Multiple Targets
Initiator Target
+-------+ +-------+
| HOST +----SCSI-Bus--------+ HDD |
| +------+ +----------+ |
+-------+ | | +-------+
| | +-------+
| +----------+OTHER |Target
| +----------+DEVICE |
| | +-------+
| | +-------+
| +----------+OTHER |Target
+-------------+DEVICE |
+-------+
c. Multiple Initiators, Multiple Targets
Initiator Target
+-------+ +-------+
| HOST +----SCSI-Bus--------+ HDD |
| +------+ +----------+ |
+-------+ | | +-------+
+-------+ | | +-------+
| HOST +------+ +----------+OTHER |Target
| +------+ +----------+DEVICE |
+-------+ | | +-------+
Initiator | | +-------+
| +----------+OTHER |Target
+-------------+DEVICE |
+-------+
**********************************************************************
F E A T U R E S
**********************************************************************
TEAC SD-340H-00 SPECIFICATION P/N 10530579-02, REV. A
Seek Time
---------
+----------------------------------+--------+
| |340H-00 |
+----------------------------------+--------+
|Track-to-Track msec. typ. | 8 * |
+----------------------------------+--------+
|Average msec. typ. | 19 * |
| msec. max. | 50 * |
+----------------------------------+--------+
|Latency msec. avg. | 8.33 |
+----------------------------------+--------+
* = including settling time
Adaptable standards
-------------------
ANSI Standard X3.131-1986 "SCSI (level 2)
ANSI Standard X3T9.2/85-52 Rev 4.B "CCS"
Driver/Receiver
---------------
Single-ended type
Bus parity
----------
Output data from the HDD: Parity is always added (odd parity)
Input data to the HDD: Parity check (odd parity) function is
optional by the strap connection in the
HDD.
Data transfer system
--------------------
Asynchronous data transfer
Formatted data capacity
-----------------------
Per logical block: 512 Bytes. However, 256 Bytes or 1,024 Bytes can
be specified by the MODE SELECT command.
Sense data
----------
The HDD shall be provided with Extended Sense Data format only.
VLD (Valid)
The VLD specifies whether or not the Information Byte is valid. When
the VLD is one (1), it indicates that the Information Byte is valid.
ERROR CLASS
The Error Class is always set to "7", which indicates that the Sense
Data is the Extended Sense Data.
ERROR CODE
The error code is always set to zero (0), which indicates that the
Sense Data is described in the Extended Dat aformat.
SENSE KEYS
The Sense Keys indicate the outline of error contents.
ADDITIONAL SENSE LENGTH
The Additional Sense Length specifies the number of Additional Sense
Bytes to follow. This is set to 0BH in the HDD.
ADDITIONAL SENSE CODE
The Additional Sense Code indicates error coded information.
Sense data (Extended)
---------------------
+------+------+------+------+------+------+------+------+------+
|Byte |bit 7 |bit 6 |bit 5 |bit 4 |bit 3 |bit 2 |bit 1 |bit 0 |
+------+------+------+------+------+------+------+------+------+
| 0 |VLD |ERROR CLASS |ERROR CODE |
| +------+------+------+------+------+------+------+------+
| | |1 |1 |1 |0 |0 |0 |0 |
+------+------+------+------+------+------+------+------+------+
| 1 |RESERVED |
| +------+------+------+------+------+------+------+------+
| |0 |0 |0 |0 |0 |0 |0 |0 |
+------+------+------+------+------+------+------+------+------+
| 2 |RESERVED |SENSE KEY |
| +------+------+------+------+------+------+------+------+
| |0 |0 |0 |0 | | | | |
+------+------+------+------+------+------+------+------+------+
| 3 |INFORMATION BYTE (MSB) |
+------+-------------------------------------------------------+
| 4 |INFORMATION BYTE |
+------+-------------------------------------------------------+
| 5 |INFORMATION BYTE |
+------+-------------------------------------------------------+
| 6 |INFORMATION BYTE (LSB) |
+------+-------------------------------------------------------+
| 7 |ADDITIONAL SENSE LENGTH |
| +------+------+------+------+------+------+------+------+
| |0 |0 |0 |0 |1 |0 |1 |1 |
+------+------+------+------+------+------+------+------+------+
| 8-11 |00H RESERVED (4 BYTES) |
+------+-------------------------------------------------------+
|12 |ADDITIONAL SENSE CODE |
+------+-------------------------------------------------------+
|13-18 |00H RESERVED (6 BYTES) |
+------+-------------------------------------------------------+
Sense Keys
----------
0H NO SENSE
1H RECOVERED ERROR
2H NOT READY
3H MEDIUM ERROR
4H HARDWARE ERROR
5H ILLEGAL REQUEST
6H UNIT ATTENTION
BH ABORTED COMMAND
EH MISCOMPARE
Additional sense code
---------------------
00 NO ADDITIONAL SENSE INFORMATION
01 NO INDEX/SECTOR SIGNAL
03 WRITE FAULT
04 DRIVE NOT READY
06 NO TRACK ZERO FOUND
09 TRACK FOLLOWING ERROR
10 ID CRC ERROR
11 UNRECOVERED READ ERROR OF DATA BLOCK
12 NO ADDRESS MARK FOUND IN ID FIELD
13 NO ADDRESS MARK FOUND IN DATA FIELD
14 NO RECORD FOUND
15 SEEK POSITIONING ERROR
19 DEFECT LIST ERROR
1C PRIMARY DEFECT LIST NOT FOUND
1D COMPARE ERROR
20 INVALID COMMAND OPERATION CODE
21 ILLEGAL LOGICAL BLOCK ADDRESS
24 ILLEGAL FIELD IN CDB
25 INVALID LUN
26 INVALID FIELD IN PARAMETER LIST
29 POWER ON OR RESET OR BUS DEVICE RESET OCCURED
2A MODE SELECT PARAMETER CHANGED
31 MEDIUM FORMAT CORRUPTED
32 NO DEFECT SPARE LOCATION AVAILABLE
40 RAM FAILURE
42 POWER ON DIAGNOSTIC FAILURE
43 MESSAGE RETECT ERROR
44 INTERVAL CONTROLLER ERROR
45 SELECT/RESELECT FAILURE
47 SCSI INTERFACE PARITY ERROR
48 INITIATOR DETECT ERROR
49 INAPPROPRIATE/ILLEGAL MESSAGE
Frame Ground
------------
The frame of the HDD (mounting holes) is connected to the DC 0V.