1 2 0 0 SIEMENS NIXDORF
NO MORE PRODUCED Native| Translation
------+-----+-----+-----
Form 5.25"/FH Cylinders 1216| | |
Capacity form/unform 171/ MB Heads 8| | |
Seek time / track 25.0/ ms Sector/track 36| | |
Controller ESDI Precompensation
Cache/Buffer 32 KB FIFO BUFFER Landing Zone
Data transfer rate 1.250 MB/S int Bytes/Sector 512
MB/S ext
Recording method RLL operating | non-operating
-------------+--------------
Supply voltage 5/12 V Temperature *C 10 45 | 3 60
Power: sleep W Humidity % 20 80 |
standby W Altitude km |
idle W Shock g |
seek W Rotation RPM 3524
read/write W Acoustic dBA
spin-up W ECC Bit
MTBF h 30000
Warranty Month
Lift/Lock/Park YES Certificates
**********************************************************************
L A Y O U T
**********************************************************************
SIEMENS MEGAFILE 1200/1300 HANDLING INSTRUCTIONS S26371-K64-V1-X7619
+---------------------------------------------------------+ 1
| +-J12 +--J9--+ J11----1 |XX
| +-+ +------+ +-----+ |XX J1
| Terminator Address |XX
| |XX
| |XX
| |XX
| |XX
| |XX
| |
| |XX1
| |XX J2
| |XX
| |XX
| |XX
| |
| |XX J3
| |XX Power
+---------------------------------------------------------+
+----------------------------------+
| |
| |
| |
| +J8 Grounding Connector |
| ++ |
| J3 J2 1 J1 1 |
| XXXXXX XXXXXXxX XXXXXXXXXXXXXXxX |
+----------------------------------+
**********************************************************************
J U M P E R S
**********************************************************************
SIEMENS MEGAFILE 1200/1300 HANDLING INSTRUCTIONS S26371-K64-V1-X7619
Jumper Setting
==============
J11 Address Jumper
------------------
+-------------+ +-------------+
|X o o o o o o| Drive 1 |o X o o o o o| Drive 2
|X o o o o o o| |o X o o o o o|
+-------------+ +-------------+
1 2 3 4 5 6 7 1 2 3 4 5 6 7
+-------------+ +-------------+
|o o X o o o o| Drive 3 |o o o X o o o| Drive 4
|o o X o o o o| |o o o X o o o|
+-------------+ +-------------+
1 2 3 4 5 6 7 1 2 3 4 5 6 7
+-------------+ +-------------+
|o o o o X o o| Drive 5 |o o o o o X o| Drive 6
|o o o o X o o| |o o o o o X o|
+-------------+ +-------------+
1 2 3 4 5 6 7 1 2 3 4 5 6 7
+-------------+
|o o o o o o X| Drive 7
|o o o o o o X|
+-------------+
1 2 3 4 5 6 7
J12 Automatic Spin up jumper (Upper than REV 130)
-------------------------------------------------
ON Automatic Spin up
OFF Power on Command
**********************************************************************
I N S T A L L
**********************************************************************
SIEMENS MEGAFILE 1200/1300 HANDLING INSTRUCTIONS S26371-K64-V1-X7619
Notes on Installation
=====================
Installation direction
----------------------
PCBA down PCBA left PCBA right
+-----------------+ +--+ +--+
| | | +-----+ +-----+ |
| | | | | | | |
+-+-----------------+-+ | | | | | |
+---------------------+ | | | | | |
| | | | | |
PCBA up | | | | | |
+---------------------+ | +-----+ +-----+ |
+-+-----------------+-+ +--+ +--+
| |
| |
+-----------------+
Recommended Cables
------------------
Interface Cable 50 Conductor flat ribbon twisted pair or equivalent
Power Cable 18 AWG wire with a 4-pin AMP Mate-N-Lok Connector P/N AMP
1-480424-0
Frame Ground 18 AWG wire with AMP P/N 61761-2 or equivalent
Optional Front Panel
--------------------
REV 1 to REV 129 No. S26371-H30-V1 (C26371-H30-C4) suitable to
(metal shielded) metal plate frame
2 LED, Red = error
Green = error
REV 130 No. S26371-H30-V2 (C26371-H30-C4) suitable to
(plastic panel) metal plate frame
1 LED, Red = drive selected
Upper than REV 131 No. S26371-H30-V3 (C26371-H23-C321) suitable to
(plastic panel) die cast frame
1 LED, Red = drive selected
Cable Interconnection
---------------------
+-----------+ +-----------------+
| +---o---Control------------------+J1 Drive 1 |
| | | +-------Data------------+J2 |
| | | | +-Power---+J3 J8 ... |
| | | | | +-----+-----------+
| | | | | +-Frame----+
| | | | | | +-----------------+
|Controller | o----+-------------+----+----+J1 Drive 2 |
| | | | +-----------+----+----+J2 |
| | | | | o----+----+J3 J8 ... |
| | | | | | | +----+------------+
| | | | | | o---------+
| | | | | | | +-----------------+
| | o----+-+-----------+----+----+J1 Drive 3 |
| | | | | +---------+----+----+J2 |
| +---+Data+ | | o----+----+J3 J8 ... |
| +---+-Data-+ | | | +-----+-----------+
| | | | | o----------+
| +---+-Data---+ | | +-----------------+
| | +------------------+----+----+J1 Drive 7 |
| +-----Data-------------+----+----+J2 |
| | o----+----+J3 J8 XXX |
+-----------+ | | +-----+-----------+
DC voltages----+ o----------+
|
Frame Ground--------+
... = Terminator Pack removed
XXX = Terminator Pack installed
Terminator installed only in the last physical drive in a chain.
Max. cable length 3 meters.
Screws
------
Mounting Holes 2 per side #6-32 UNC-2B 0.14 (3.5) deep (4x)
Mounting Holes 4 on bottom #6-32 UNC-2B, 0.4 (10) deep (4x)
NOTE
Mounting Holes 2 per side are different in depth to the mounting
holes 4 on bottom.
J3 DC Power and pin connector assignments
-------------------------------------------
pin 1 +12 VDC
pin 2 +12 Volts Return
pin 3 + 5 Volts Return
pin 4 + 5 VDC