S E Q - 4 3 8 0 E    SEQUEL
NO MORE PRODUCED                                      Native|  Translation
                                                      ------+-----+-----+-----
Form                 5.25"/FH              Cylinders    1224|     |     |
Capacity form/unform   338/  384 MB        Heads          15|     |     |
Seek time   / track  17.0/ 3.0 ms          Sector/track   36|     |     |
Controller           ESDI                  Precompensation
Cache/Buffer               KB              Landing Zone
Data transfer rate    1.250 MB/S int       Bytes/Sector      512
                            MB/S ext
Recording method     RLL 1/7                        operating  | non-operating
                                                  -------------+--------------
Supply voltage     5/12 V       Temperature *C        10 55    |    -40 60
Power: sleep              W     Humidity     %         8 80    |      8 80
       standby            W     Altitude    km            3.048| -0.305 12.192
       idle               W     Shock        g         2       |     25
       seek               W     Rotation   RPM      3600
       read/write    27.0 W     Acoustic   dBA
       spin-up            W     ECC        Bit
                                MTBF         h     150000
                                Warranty Month        24
Lift/Lock/Park     YES          Certificates     CSA,FCC,IEC380,UL1950,VDE


**********************************************************************
                        L   A   Y   O   U   T
**********************************************************************
MAXTOR   XT-4000E FAMILY  QUICK REFERENCE GUIDE 1018329 REV. B

  +----------------+--------+-------------------------------+
  |                +--J4----+    JP42++JP1                  |XX
  |                      +-JP41     ++++                    |XX J2
  |                      +-+                                |XX
  |                                                         |XX
  |                                                 DS1-DS7 |
  |                                             E15+++++++++|XX
  |                       JP24 - 16               ++++++++++|XX
  |                       ++++++++++              +-RN13---+|XX
  |                       ++++++++++              +--------+|XX J1
  |                   JP25-31+++++++   +--JP45    +-RN14---+|XX
  |                         ++++++++   +--+       +--------+|XX
  +-J5                     +++++++++                        +-+
  | |                      +++++++++                 JP14+ J6+|
  | |                     JP39 - 32                     ++ +-+|
  +-+                  ++                                   +-+
  |                    +JP6                                 |XX J3
  |                                                         |XX Power
  +---------------------------------------------------------+



**********************************************************************
                      J   U   M   P   E   R   S
**********************************************************************
MAXTOR   XT-4000E FAMILY  QUICK REFERENCE GUIDE 1018329 REV. B

 Jumper Setting
 ==============

 x = Jumper set at factory

 Jumper Selections
 -----------------
  +------------+--------------------------------------------+
  |JP1 (IN)    |Used for Manufacturing Testing              |
  +------------+--------------------------------------------+
  |JP6 (IN)    |IN = Motor Spinup Option Disabled           |
  |            |OUT = Remote Motor Spinup Option Enabled    |
  +------------+--------------------------------------------+
  |DS1-DS7     |Drive Select                                |
  +------------+--------------------------------------------+
  |JP14 (OUT)  |IN = Write Protected                        |
  |            |OUT = No Write Protection                   |
  +------------+--------------------------------------------+
  |JP16-JP29   |Unformatted Hard Sector Size in Bytes       |
  |            |Jumpers, LSB = JP16, MSB = JP29             |
  +------------+--------------------------------------------+
  |JP30        |IN = Enables Programming of the Hard Sector |
  |            |Size through the interface                  |
  |            |OUT = Disable this Function                 |
  +------------+--------------------------------------------+
  |JP31        |IN = Soft Sector Mode                       |
  |            |OUT = Hard Sector Mode                      |
  +------------+--------------------------------------------+
  |JP32-35,JP38|PCB Head Configuration                      |
  +------------+--------------------------------------------+
  |JP41        |Test Connection, not a jumperable Option    |
  +------------+--------------------------------------------+
  |JP42 (IN)   |Used for Manufacturing Testing              |
  +------------+--------------------------------------------+
  |JP45        |Used for Conversion to Short Index          |
  |            |1, 2 = Standard Index (70 S), 2, 3 Short    |
  |            |Index (3 S)                                 |
  +------------+--------------------------------------------+
  |Note: JP4, JP5, JP15, JP36, JP39, JP40, JP41 are NOT     |
  |Jumperable Options. The only Customer Configurable       |
  |Options are JP6, JP14, JP16-JP29, JP30, JP31, JP45, and  |
  |DS1-DS7.                                                 |
  +---------------------------------------------------------+



 Drive Address Selection
 -----------------------
   +------------+-----------+
   |Drive Select| Jumper    |
   |Number      | Installed |
   +------------+-----------+
   | x 1        |    DS1    |
   +------------+-----------+
   |   2        |    DS2    |
   +------------+-----------+
   |   3        |    DS3    |
   +------------+-----------+
   |   4        |    DS4    |
   +------------+-----------+
   |   5        |    DS5    |
   +------------+-----------+
   |   6        |    DS6    |
   +------------+-----------+
   |   7        |    DS7    |
   +------------+-----------+

 In multidrive configurations, it is necessary to configure each drive
 with a unique address. A maximum of seven drives are permitted per
 single host controller. The address for the drive is determined by
 installing the jumper plug in the appropriate jumper location.
 As shipped from the factory, the drive is configured as logical unit
 number one. Removing the jumper entirely is equivalent to a "no
 select".


 JP6  Option for Sequential Spindle Motor Spinup Jumper
 ------------------------------------------------------
    x JP6  CLOSED  The drive automatically spins up as soon as power
                   is applied.
           OPEN    The drive is started be issuing the appropriate
                   command from the controller.

 The spindle motor spinup jumper allows a string of drives to be
 started sequentially by the controller.


 JP14  Write Protect Selection Jumper
 ------------------------------------
      JP14  CLOSED  The drive is write protected and can only be read;
                    no writing may take place.
    x       OPEN    The drive is not write protected.



 JP16-JP31  Hard Sector Configuration Jumpers
 --------------------------------------------
 Jumper JP31 selects the mode of operation. Jumper JP31 installed
 configures the drive as a soft sectored drive; removed, it configures
 the drive as a hard sectored drive.

 Jumpers JP16 through JP29 allow the user to configure the drive's
 hard sector size. The sector size can range from a minimum of 123 to
 a maximum of 10,470 unformatted bytes per sector, with 1 byte
 granularity.

 The hard sector configuration jumpers are encoded in a binary
 fashion, with JP16 being the least significant byte and JP29 being
 the most significant byte. An installed jumper equates to a one.

 Jumper JP30, if installed, enables setting the hard sector size over
 the ESDI interface. The drive must be in hard sector mode, (i.e. JP31
 removed).

    +-----------+---------------+
    | Jumper    |# Bytes/Sector |
    +-----------+---------------+
    | J16       |      1        |
    +-----------+---------------+
    | J17       |      2        |
    +-----------+---------------+
    | J18       |      4        |
    +-----------+---------------+
    | J19       |      8        |
    +-----------+---------------+
    | J20       |     16        |
    +-----------+---------------+
    | J21       |     32        |
    +-----------+---------------+
    | J22       |     64        |
    +-----------+---------------+
    | J23       |    128        |
    +-----------+---------------+
    | J24       |    256        |
    +-----------+---------------+
    | J25       |    512        |
    +-----------+---------------+
    | J26       |  1,024        |
    +-----------+---------------+
    | J27       |  2,048        |
    +-----------+---------------+
    | J28       |  4,096        |
    +-----------+---------------+
    | J29       |  8,192        |
    +-----------+---------------+


 Example: 36 Sectors Desired

 1. 20,940
    ------ = 581 Bytes/Sector
      36

 2: Install Jumpers J25 + J22, J18, +J16
    # Bytes/Sector 512 + 64 + 4 + 1 = 581


 JP32-35, JP38  Data Head Selection Jumpers
 ------------------------------------------
  +--------+-----------+----------------------------------+
  |Drive   |Number of  |    Jumper Configuration          |
  |Model   |Data Heads |JP32  |JP33  |JP34  |JP35  |JP38  |
  +--------+-----------+------+------+------+------+------+
  |XT-4170E|    7      |CLOSED|CLOSED|CLOSED|OPEN  |OPEN  |
  +--------+-----------+------+------+------+------+------+
  |XT-4230E|    9      |CLOSED|CLOSED|CLOSED|OPEN  |CLOSED|
  +--------+-----------+------+------+------+------+------+
  |XT-4380E|   15      |CLOSED|CLOSED|CLOSED|CLOSED|OPEN  |
  +--------+-----------+------+------+------+------+------+

 Jumpers have been provided to allow the number of usable data heads
 to be selected. In order for the drive to respond correctly to the
 request configuration command - number of heads, these jumpers are
 set at the factory to correspond with the model of the drive.


 JP41, JP42, JP1  Test Jumpers
 -----------------------------

  +-------+---------+--------------------------+
  |Jumper | Factory | Notes on Function        |
  |       | Setting |                          |
  +-------+---------+--------------------------+
  | JP1   | CLOSED  | Write Data               |
  +-------+---------+--------------------------+
  | JP41  | N/A     | Test Pins, Not Jumperable|
  +-------+---------+--------------------------+
  | JP42  | CLOSED  | Write Gate               |
  +-------+---------+--------------------------+

 These jumpers provide access to certain test signals.


 J6 Spindle Synchronization
 --------------------------
 Jumper J6 is the spindle synchronization connector and is connected
 to the drives using this option.


 J3   DC Power and pin connector assignments
 -------------------------------------------
      +------------+   pin 1    +12 VDC
      | 4  3  2  1 |   pin 2    +12 Volts Return
      +------------+   pin 3    + 5 Volts Return
                       pin 4    + 5 VDC



**********************************************************************
                      I   N   S   T   A   L   L
**********************************************************************
MAXTOR   XT-4000E FAMILY  QUICK REFERENCE GUIDE 1018329 REV. B

 Notes on Installation
 =====================

 Installation direction
 ----------------------

     horizontally                           vertically
   +-----------------+             +--+                       +--+
   |                 |             |  +-----+           +-----+  |
   |                 |             |  |     |           |     |  |
 +-+-----------------+-+           |  |     |           |     |  |
 +---------------------+           |  |     |           |     |  |
                                   |  |     |           |     |  |
                                   |  |     |           |     |  |
 +---------------------+           |  +-----+           +-----+  |
 +-+-----------------+-+           +--+                       +--+
   |                 |
   |                 |
   +-----------------+

 Mounting
 --------
 The drive may be mounted in any orientation. In any final mounting
 configuration, ensure that the operation of the three shock mounts
 which, isolate the base casting from the frame is not restricted.


 Mounting Holes
 --------------
 Eight mounting holes, four on the bottom and two on each side, are
 provided for mounting the drive into an enclosure. The size and
 location of these holes are identical to industry standard floppy
 drives.

 Caution: The casting is very close to the frame mounting holes in
 some locations. Mounting screws lengths must be chosen such that no
 more than 0.125 inch of the screw is available to enter the frame
 mounting hole. The torque applied to the mounting screws must be
 between 9 and 12 inch pounds.


 J1/P1 SCSI Connector
 --------------------
 Connection to J1 is via a 34-pin PCB edge connector. The pins are
 numbered 1 through 34 with the even pins located on the component
 side of the PCB. Pin 2 is located on the end of the PCB connector
 closest to the DC power connector J3/P3. A key slot is provided be-
 tween pins 4 and 6. The recommended mating connector for P1 is AMP
 ribbon connector P/N 88373-3 or equivalent.

 J2/P2 Connector
 ---------------
 Connection of J2 is via a 20-pin PCB edge connector. The pins are
 numbered 1 through 20 with the even pins located on the component
 side of the PCB. The recommended mating connector for P2 is AMP
 ribbon connector P/N 88373-6. A key slot is provided between pins 4
 and 6.


 J3/P3 Power Connector
 ---------------------
 The DC power connector, J3, is a four-pin AMP MATE-N-LOCK connector
 justify margin P/N 350543-1 mounted on the solder side of the PCB.
 The recommended mating connector is P/N 1-480424-0 using AMP pins
 part number 350078-4 (strip) or part number 61173-4 (loose piece).


 J4/P4 Ground
 ------------
 The frame ground connector is a Faston-type connector, AMP part
 number 61761-2. The recommended mating connector is AMP part number
 62187-1. If wire is used, the hole in J4 will accommodates a maximum
 wire size of 18 AWG.


 J6/P6 Auxiliary Connector
 -------------------------
 The auxiliary connector is a Berg 68451-121 ten-pin connector. The
 mating connector is a 3M 3473-6010.
     +----------------------+---+
     |Signal Name           |Pin|
     +----------------------+---+
     |MAPOUT                | 1 |
     +----------------------+---+
     |MAPIN                 | 2 |
     +----------------------+---+
     |GND                   | 3 |
     +----------------------+---+
     |MAPIN                 | 4 |
     +----------------------+---+
     |GND                   | 5 |
     +----------------------+---+
     |KEY (N.C.)            | 6 |
     +----------------------+---+
     |- REMOTE WRITE PROTECT| 7 |
     +----------------------+---+
     |                      | 8 |
     +----------------------+---+
     |- LED                 | 9 |
     +----------------------+---+
     |+ LED                 |10 |
     +----------------------+---+


 Removable Faceplate
 -------------------
 The faceplate may be removed in installations where it is not
 required. Remove the two C-clips and unplug the LED cable from the
 PCB.



**********************************************************************
                      F   E   A   T   U   R   E  S
**********************************************************************
MAXTOR   XT-4000E FAMILY  QUICK INSTALLATION GUIDE 1018329 REV. B



 Seek Time
 ---------
                                        | 4170E  | 4230E  | 4380E  |
      ----------------------------------+--------+--------+--------+
      Track-to-Track         msec. typ. |   2.5  |   2.5  |   2.5  |
                             msec. max. |   3    |   3    |   3    |
      ----------------------------------+--------+--------+--------+
                     Average msec. typ. |  14    |   16   |   16   |
                     Average msec. max. |  16    |   17   |   18   |
      ----------------------------------+--------+--------+--------+
      Full Stroke            msec. typ. |  27    |   29   |   29   |
                             msec. max. |  34    |   34   |   34   |
      ----------------------------------+--------+--------+--------+
      Latency                msec. avg. |   8.33 |    8.33|    8.33|
      ----------------------------------+--------+--------+--------+

 Seek Time includes Settling Time.


 Reliability Specifications
 --------------------------
 MTBF                    150,000 Hours
 PM                     None Required
 MTTR                   30 Minutes
 Component Design Life  5 Years



Hosted by uCoz