M R 5 3 5 R    MITSUBISHI
NO MORE PRODUCED                                      Native|  Translation
                                                      ------+-----+-----+-----
Form                 5.25"/HH              Cylinders     977|     |     |
Capacity form/unform    60/      MB        Heads           5|     |     |
Seek time   / track  28.0/ 5.0 ms          Sector/track   26|     |     |
Controller           RLL / ST506           Precompensation   300
Cache/Buffer               KB              Landing Zone
Data transfer rate    0.938 MB/S int       Bytes/Sector      512
                      0.938 MB/S ext
Recording method     RLL 2/7                        operating  | non-operating
                                                  -------------+--------------
Supply voltage     5/12 V       Temperature *C        10 50    |    -40 60
Power: sleep              W     Humidity     %         8 80    |      5 95
       standby            W     Altitude    km            2.000|        12.000
       idle               W     Shock        g         2       |     30
       seek          20.0 W     Rotation   RPM      3600
       read/write         W     Acoustic   dBA
       spin-up            W     ECC        Bit   32
                                MTBF         h      30000
                                Warranty Month
Lift/Lock/Park     YES          Certificates                                  

**********************************************************************
                        L   A   Y   O   U   T
**********************************************************************
MITSUBI. MR535  OPERATION AND MAINTENANCE MANUAL IB-67124-A

  +---------------------------------------------------------+
  |                                                         |XX
  |                                                         |XX J2
  |                                                         |XX
  |                                                         |XX
  |                                              SW2 8--+   |  1
  |                                                  |  |   |XX
  |                                                  |  |   |XX
  |                                                  |  |   |XX
  |                                                  |  |   |XX
  |                                                  1--+   |XX J1
  |                                              SW1 6--+   |XX
  |                                                  |  |   |XX
  |                                                  |  |   |XX
  |                                                  1--+   |XX
  |                                                         |  1
  |                                                         |XX J6
  |                                                         |XX Power
  +---------------------------------------------------------+  1



**********************************************************************
                      J   U   M   P   E   R   S
**********************************************************************
MITSUBI. MR535  OPERATION AND MAINTENANCE MANUAL IB-67124-A

 Jumper Setting
 ==============

 There are two switches on the main circuit board of this drive.


 SW1 Termination Switch
 ----------------------
        +-----------+
        |o o o o o o|ON
        |x x x x x x|OFF
        +1-2-3-4-5-6+
         +-+-+-+-+-+------- Termination Switch

 To provide termination for the last unit, al switches of SW1 should
 be set in the ON position. On all other units, all the switches of
 SW1 should be set in the OFF position.


 SW2  Drive Select
 -----------------
        +---------------+
        |x o o o x o o o|ON
        |o x x x o x x x|OFF
        +1-2-3-4-5-6-7-8+
         | | | | | | | +---  Set OFF position
         | | | | | | +-----  Set OFF position
         | | | | | +-------  Set OFF position
         | | | | +---------  RADIAL (R)
         | | | +-----------  Drive Select 1 (DS1)
         | | +-------------  Drive Select 2 (DS2)
         | +---------------  Drive Select 3 (DS3)
         +-----------------  Drive Select 4 (DS4)


 In multiple unit connection it is necessary to configure each drive
 with a unique address.

   +-----------+---------------------------+
   |   SW2     |Drive Select Configuration |
   +----+------+------+-----+----+---------+
   |Bit |*Mark |   1  |  2  |  3 |  4      |
   +----+------+------+-----+----+---------+
   | 1  | DS1  |   ON | OFF |OFF |OFF      |
   +----+------+------+-----+----+---------+
   | 2  | DS2  |   OFF| ON  |OFF |OFF      |
   +----+------+------+-----+----+---------+
   | 3  | DS3  |   OFF| OFF |ON  |OFF      |
   +----+------+------+-----+----+---------+
   | 4  | DS4  |   OFF| OFF |OFF |ON       |
   +----+------+------+-----+----+---------+
  *Mark is printed on Printed Circuit Board (PCB).


 The control cable allows for a daisy chain connection of up to four
 drives.

 The switch block has DRIVE SELECT switched off with the "radial"
 option selected. Each drive is shipped with the switch block marked
 "R" switched on, resulting in the daisy chain operation. In this
 case, input and output signals are enabled when the appropriate
 DRIVE SELECT line is activated.

 When the switch block marked "R" is switched off, all inout and out-
 put signals are enabled even if the drive is not selected.

 However, the front panel LED will not be on. DRIVE SELECT must be
 activate to light the LED.




 J6   DC Power and pin connector assignments
 -------------------------------------------
     +--------------+
     |+-----J3-----+|  pin 1    +12 VDC
     || 1  2  3  4 ||  pin 2    +12 VDC Return
     |+------------+|  pin 3    + 5 VDC Return
     +--------------+  pin 4    + 5 VDC