K C   3 0 C    KYOCERA
NO MORE PRODUCED                                      Native|  Translation
                                                      ------+-----+-----+-----
Form                 3.5"/HH               Cylinders     615|     |     |
Capacity form/unform    33/   39 MB        Heads           4|     |     |
Seek time   / track  62.0/15.0 ms          Sector/track   26|     |     |
Controller           RLL / ST506           Precompensation
Cache/Buffer               KB              Landing Zone
Data transfer rate    0.938 MB/S int       Bytes/Sector      512
                      0.938 MB/S ext
Recording method     RLL 2/7                        operating  | non-operating
                                                  -------------+--------------
Supply voltage     5/12 V       Temperature *C         5 50    |    -40 60
Power: sleep              W     Humidity     %         8 80    |      5 90
       standby            W     Altitude    km    -0.300  3.000| -0.300 12.000
       idle               W     Shock        g        10       |     40
       seek               W     Rotation   RPM      3600
       read/write         W     Acoustic   dBA        40
       spin-up            W     ECC        Bit
                                MTBF         h      40000
                                Warranty Month
Lift/Lock/Park     NO           Certificates                                  

**********************************************************************
                        L   A   Y   O   U   T
**********************************************************************
KYOCERA  KC-20B/30B  TECHNICAL MANUAL (DEUTSCHES HANDBUCH)

  +---------------------------------------------------------+
  |                                                         |XX
  |                                                         |XX P2
  |                                                         |XX
  |                                                         |XX
  |                                                         |XX1
  |                                                   +-+   |
  |                                                   +-+S4 |XX
  |                                                   +-+S3 |XX
  |                                                   +-+S2 |XX
  |                                                   +-+S1 |XX P1
  |                                                    ++   |XX
  |                                                    |RN1 |XX
  |                                                    ||   |XX
  |                                                    ||   |XX
  |                                                   1++   |XX1
  |                                                       P3|
  |                                                  XXXXXXX|Power
  +---------------------------------------------------------+



**********************************************************************
                      J   U   M   P   E   R   S
**********************************************************************
KYOCERA  KC-20B/30B  TECHNICAL MANUAL (DEUTSCHES HANDBUCH)

 Jumper Setting
 ==============

 J2  SCSI ID
 -----------
   +----------+-------------------------------+
   | Drive    |        Jumpers                |
   | Select   |  S1   |  S2   |  S3   |  S4   |
   +----------+-------+-------+-------+-------+
   |    0     | CLOSED| OPEN  | OPEN  | OPEN  |
   |    1     | OPEN  | CLOSED| OPEN  | OPEN  |
   |    2     | OPEN  | OPEN  | CLOSED| OPEN  |
   |    3     | OPEN  | OPEN  | OPEN  | CLOSED|
   +----------+-------+-------+-------+-------+


 J3   DC Power and pin connector assignments
 -------------------------------------------
      +-----J3-----+   pin 1    +12 VDC
      | 4  3  2  1 |   pin 2    +12 Volts Return
      +------------+   pin 3    + 5 Volts Return
                       Pin 4    + 5 VDC