M 1 6 0 3 S A U < 1 1 / 1 9 9 5 FUJITSU NO MORE PRODUCED Native| Translation ------+-----+-----+----- Form 3.5"/SLIMLINE Cylinders 3456| | | Capacity form/unform 544/ MB Heads 3| | | Seek time / track 10.0/ 3.0 ms Sector/track | | | Controller SCSI2 SI/FAST Precompensation Cache/Buffer 512 KB SEGMENTED Landing Zone Data transfer rate 5.500 MB/S int Bytes/Sector 512 10.000 MB/S ext SYNC Recording method RLL 1/7 operating | non-operating -------------+-------------- Supply voltage 5/12 V Temperature *C 5 55 | -40 60 Power: sleep W Humidity % 8 80 | 5 95 standby W Altitude km -0.300 3.000| -0.300 12.000 idle W Shock g 5 | 50 seek W Rotation RPM 5400 read/write W Acoustic dBA 38 spin-up W ECC Bit MTBF h 800000 Warranty Month 24 Lift/Lock/Park YES Certificates ********************************************************************** L A Y O U T ********************************************************************** FUJITSU M1603S/M1606S JUMPER SETTING A1CA 01310-0011 +---------------------------------------------------------+ | CNH1 +----+ |XX | 1+-+ | | |XXI | CN6 | | | | |XXN | ++++++ +-+8|RP1 | |XXT | +----+ |TERM| |XXE | 10 2 | | |XXR | 9 1 +----+ |XXF | |XXA | |XXC | |XXE | |XX | 2 1 |XX | +-+ CN5 |XX | +-+ | +5V | |XX | |XX +---------------------------------------------------------+ +12V Drives manufactured before November 1995! ********************************************************************** J U M P E R S ********************************************************************** FUJITSU M1603S/M1606S JUMPER SETTING C1CA 01310-0011 Jumper Setting ============== x = Factory default setting CNH1 SCSI ID ------------- +----------+-----------------------+ | SCSI ID | Jumpers | | | 5-6 | 3-4 | 1-2 | +----------+-------+-------+-------+ |x 0 | OPEN | OPEN | OPEN | +----------+-------+-------+-------+ | 1 | OPEN | OPEN | CLOSED| +----------+-------+-------+-------+ | 2 | OPEN | CLOSED| OPEN | +----------+-------+-------+-------+ | 3 | OPEN | CLOSED| CLOSED| +----------+-------+-------+-------+ | 4 | CLOSED| OPEN | OPEN | +----------+-------+-------+-------+ | 5 | CLOSED| OPEN | CLOSED| +----------+-------+-------+-------+ | 6 | CLOSED| CLOSED| OPEN | +----------+-------+-------+-------+ | 7 | CLOSED| CLOSED| CLOSED| +----------+-------+-------+-------+ NOTE Always ensure that the device ID selected is unique to the SCSI bus. The controller is often configured at ID 7 so it is the best to avoid this ID number for the drive. CNH1 Spindle Motor Control -------------------------- Pins 7-8 OPEN By Command xCLOSED Auto CN6 Remote SCSI ID Connector ---------------------------- +1-3-5-7-9+ |o o o o o| Side View |o o o o o| +2-4-6-8-10 +------------+--------+ | PINS | SIGNAL | +------------+--------+ |Pin 2 |-ID0 | +------------+--------+ |Pin 4 |-ID1 | +------------+--------+ |Pin 6 |-ID2 | +------------+--------+ |Pins 1, 3, 5|GND | +------------+--------+ |Pins 7 10 |RESERVED| +------------+--------+ CN5 External operator panel connector ------------------------------------- Pin 01 LED(V) Pin 02 -LED ********************************************************************** I N S T A L L ********************************************************************** FUJITSU M1603S/M1606S JUMPER SETTING A1CA 01310-0011 Notes On Installation ===================== Drive mounting -------------- horizontally vertically +-----------------+ +--+ +--+ +------------------+ | | | +-----+ +-----+ | | | x | | | | | | | | x+----------------+x +-+-----------------+-+ | | | | | | ||x x|| +---------------------+ | | | | | | || x x || | | | | | | || x x || x x | | | | | | || x x || +------x------x-------+ | +-----+ +-----+ | || xx || +-+------x--x-------+-+ +--+ +--+ || x x || | xx | || x x || | x x | || x x || +---x--------x----+ |x x| x x x++----------------++x UNACCEPTABLE! UNACCEPTABLE! Orientation ----------- The drive may be installed in one of three orientations; PCA down or on either edge. Inclination from vertical or horizontal should not exceed 5*. Mounting screw fixing --------------------- When the mounting screw holes on the side of the drive are used, then use only the two pairs of outer holes. Do not use the centre hole in conjunction with only one of the outer holes. The screw must not penetrate the drive by more than 4.5 millimetres. Grounding --------- Sufficient grounding will be provided for correct operation when the drive is screwed into an electrically grounded frame. Cooling ------- Allow space above and below the drive to provide for adequate air flow. Fan cooling is recommended. The disk enclosure temperature, measured at top centre, should never exceed 60*C. Termination ----------- A terminating resistor should be installed at both ends of the SCSI bus. When shipped from the factory, this drive is terminated. If the drive is to be used in the middle of the SCSI cable with other terminated devices at the ends, or if external termination is to be used, then the terminating resistor pack on the drive MUST be removed. Termination Power ----------------- Terminator power is supplied internally and to the SCSI BUS via a fuse. M 1 6 0 3 S A U > 1 1 / 1 9 9 5 FUJITSU NO MORE PRODUCED Native| Translation ------+-----+-----+----- Form 3.5"/SLIMLINE Cylinders 3456| | | Capacity form/unform 544/ MB Heads 3| | | Seek time / track 10.0/ 3.0 ms Sector/track | | | Controller SCSI2 SI/FAST Precompensation Cache/Buffer 512 KB FIFO RING Landing Zone Data transfer rate 6.000 MB/S int Bytes/Sector 512 10.000 MB/S ext SYNC Recording method operating | non-operating -------------+-------------- Supply voltage 5/12 V Temperature *C 5 55 | -40 60 Power: sleep W Humidity % 8 80 | 5 95 standby W Altitude km -0.300 3.000| -0.300 12.000 idle W Shock g 5 | 505 seek W Rotation RPM 5400 read/write W Acoustic dBA 38 spin-up W ECC Bit MTBF h 800000 Warranty Month 24 Lift/Lock/Park YES Certificates ********************************************************************** L A Y O U T ********************************************************************** FUJITSU M1603S/1606S AFTER NOVEMBER 1995 JUMPER SETTING +---------------------------------------------------------+ | |XXI | CNH1----+ |XXN | +----+ |XXT | +--+ |XXE | +--CN6 |XXR | |XXF | |XXA | +--+ |XXC | +--CNH3 |XXE | |XX | |XX | |XX | |XX | +-1 | | +-+CN5 |XX Power | After 11/1995 |XX +---------------------------------------------------------+ ********************************************************************** J U M P E R S ********************************************************************** FUJITSU M1603S/1606S AFTER 11/95 JUMPER SETTING Jumper Setting ============== x = Factory default setting CNH1 SCSI ID ------------- +----------+-----------------------+ | SCSI ID | Jumpers | | | 5-6 | 3-4 | 1-2 | +----------+-------+-------+-------+ | 0 | OPEN | OPEN | OPEN | +----------+-------+-------+-------+ | 1 | OPEN | OPEN | CLOSED| +----------+-------+-------+-------+ | 2 | OPEN | CLOSED| OPEN | +----------+-------+-------+-------+ | 3 | OPEN | CLOSED| CLOSED| +----------+-------+-------+-------+ | 4 | CLOSED| OPEN | OPEN | +----------+-------+-------+-------+ | 5 | CLOSED| OPEN | CLOSED| +----------+-------+-------+-------+ | 6 | CLOSED| CLOSED| OPEN | +----------+-------+-------+-------+ |x 7 | CLOSED| CLOSED| CLOSED| +----------+-------+-------+-------+ NOTE Always ensure that the device ID selected is unique to the SCSI bus. CNH1 Spindle Motor Control -------------------------- Pins 7-8 OPEN Spindle motor controlled by START/STOP command xCLOSED Spindle motor on at power up CNH1 Synchronous Data Transfer Mode ----------------------------------- Pins 9-10 CLOSED Synchronous Data Transfer Mode disabled (default) OPEN Synchronous Data Transfer Mode enabled CNH1 Reselection retry ---------------------- Pins 11-12 CLOSED Reselection retry = unlimited (default) OPEN Reselection retry = 10 times CNH1 NOT USED ------------- Pins 13-14 NOT USED! CNH1 Active termination ----------------------- Pins 15-16 CLOSED Active termination enabled (default) OPEN Active termination disabled CN6 Remote SCSI ID Connector ---------------------------- +1-3-5-7-9+ |o o o o o| Side View |o o o o o| +2-4-6-8-10 +------------+----------+ | PINS | SIGNAL | +------------+----------+ |Pin 2 |-ID0 | +------------+----------+ |Pin 4 |-ID1 | +------------+----------+ |Pin 6 |-ID2 | +------------+----------+ |Pins 1,3,5,9|GND | +------------+----------+ |Pins 7-8 |RESERVED | +------------+----------+ |Pin 10 |Spindle | | |Sync pulse| +------------+----------+ CNH3 Terminal SCSI Termination Power ------------------------------------ 1-2 CLOSED Power is supplied to the terminating resistor from the 3-4 CLOSED IDD and TERMPWR pin. Power is also supplied to the (default) TERMPWR pin from the IDD. (Pin 26 of the interface) 1-2 CLOSED The Termpwr pin is not used. Power is supplied to the 3-4 OPEN IDD terminating resistor only from the IDD. 1-2 OPEN Power is not supplied to the terminating resistor from 3-4 CLOSED the IDD, only from the TERMPWR pin. CN5 External operator panel connector ------------------------------------- Pin 01 LED(V) Pin 02 -LED